FENCE PANEL CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws.

GATE CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws. Framed on each side of the gate; wider gates (over 6′ single gates, over 12′ double gates) include U-Frame. Welded at every picket-to-rail connection.

ResidentialCommercialINDUSTRIAL
Powder Coat Colors9 colors to choose from
no cost difference
9 colors to choose from
no cost difference
9 colors to choose from
no cost difference
Vertical Pickets5/8″ sq. x .050″ (thick)
Pickets go through maximus rail
3/4″ sq. x .055″ (thick)
Pickets go through maximus rail
1″ sq. x .062″ (thick)
Pickets go through maximus rail
Picket Spacing
W/O Rings Styles 1, 2, 3, 4, 7, 8, 9 and 10
3 13/16 inches3 5/8 inches3 5/8 inches
Picket Spacing
with Rings Styles 1, 2, 3, 4, 7, 8, 9 and 10
3 3/4 inches3 3/4 inches3.750 inches
Picket Spacing
Styles 7 & 8 double pickets
1 5/8 inches1 1/2 inches1 1/2 inches
Horizontal Rails1″ x 1 1/8″
side wall = .082″ (thick)
top wall = .062″ (thick)
8 METAL INTERNAL RIBS
1 1/4″ x 1 3/8″
side wall = .088″ (thick)
top wall = .065″ (thick)
8 METAL INTERNAL RIBS
1 5/8″ x 1 5/8″
side wall = .100″ (thick)
top wall = .070″ (thick)
8 METAL INTERNAL RIBS
Fence Panel Heights3 feet, 3 1/2 feet, 4 feet,
4 1/2 feet, 5 feet, 6 feet
3 feet, 3 1/2 feet, 4 feet,
4 1/2 feet, 5 feet, 6 feet
4′, 5′, 6′, 7′, 8′
HEIGHTS
*Fence Panel WIDTHS5′, 6′ & *7′ WIDE
TRIM TO FIT ON-SITE
6′ WIDE and *8′ WIDE
TRIM TO FIT ON-SITE
6′ wide and *8′ wide
TRIM TO FIT ON-SITE
Single Swing Gate WIDTHSOPENINGS up to 6 FEET WIDE
FRAMED & WELDED
OPENINGS up to 8 FEET WIDE
FRAMED & WELDED
OPENINGS up to 10 FEET WIDE
FRAMED & WELDED
Driveway / Estate Gate WIDTHSOPENINGS up to 12 FEET WIDE
FRAMED & WELDED
OPENINGS up to 16 FEET WIDE
FRAMED
& WELDED
OPENINGS up to 20 FEET WIDE
FRAMED & WELDED
Gate Frame2″ x 2″ x .080″ square2″ x 2″ x .080″ square2.5″ x 2.5″ x .100″ square
Gate U-Frame2 2″ x 2″ x .080″ square 2″ x 2″ x .080″ square 2.5″ x 2.5″ x .100″ square
Materials6005-T5 – 35,000 psi Aluminum Alloy6005-T5 – 35,000 psi Aluminum Alloy6005-T5 – 35,000 psi Aluminum Alloy
Material Origin100% Made in the USA100% Made in the USA100% Made in the USA
WarrantyLifetime Warranty on materials and paint finishLifetime Warranty on materials and paint finishLifetime Warranty on materials and paint finish

* Style 10: 2-RAIL FLAT TOP fence panel is not available in 7′ wide or 8′ wide sections because this style has only 2 horizontal rails. Instead, use Flat Top, Flush Bottom Rail (Style 9) which is available in these wider sections.

NOTE: It’s not common to mix fence panel grades (residential, commercial, industrial) within the same fence run because the pickets and rails increase in size. It is common for home owners to order Residential Fence Panels along with Commercial and/or Industrial Gates for those home applications that have wide driveways

Ships to your home or business anywhere in the USA!

  Testing Competition
AAMA 2603
GREATFENCE.com
AAMA 2604-5
 


Pre-
treatment

Metal Preparation
and Pretreatment
Multi-Stage Cleaning and Pretreatment Multi-Stage Cleaning and Pretreatment
Pretreatment Type Chemical Conversion Coating Chrome or Non-Chrome Chemical
Conversion Coating
Pretreatment
Coating Weight
None Specified Chrome @ 30mg/ft² Minimum;
Non-Chrome per Supplier’s Specs
 

 

Paint Film

Dry Film
Thickness
0.8 mils min. 1.2 mils (for Multi-coat, 1.0 mil Topcoat
min & 0.3+/-0.1 mil Primer
Sealant
Compatibility
Meets AAMA 800 Meets AAMA 800
Specular Gloss +/-5 Units of Specification
(high = 80+, medium+20-79, low 19-)
+/-5 Units of Specification
(high = 80+, medium+20-79, low 19-)
Dry Film
Hardness
H Minium F Minimum
 

 

Adhesion

Dry Adhesion 0% Failure (No Loss) 0% Failure (No Loss)
Wet Adhesion 0% Failure (No Loss) 0% Failure (No Loss)
Boiling Water
Adhesion
None Specified 0% Failure (No Loss)
Impact
Resistance
No Removal of Film from Substrate No Removal of Film from Substrate
Abrasion
Resistance
None Specified Abrasion Coefficient Value = 20 Min
 



Chemical
Resistance

Muriatic Acid
Resistance
15 Minute Exposure: No Blistering or Visual Change for AAMA 2603, 2604, 2605
Mortar
Resistance
24 Hour Exposure: No Loss of Film Adhesion or Visual Change for AAMA 2603, 2604, 2605
Nitric Acid
Resistance
None Specified 30 Minute Exposure: 5 Delta E (Hunter)
Maximum Color Change
Detergent
Resistance
72 Hour Exposure: No Loss of Film Adhesion, No Blistering or
No Significant Visual Change for AAMA 2603, 2604, 2605
Window
Cleaner
Resistance
None Specified 24 Hour Exposure: No Blistering
or Visual Change



Corrosion
Resistance
Humidity Resistance 1500 Hours: No More than "Few" Blisters
Size 8, Figure #4 (ASTM D 714)
3000 Hours: No More than "Few" Blisters
Size 8, Figure #4 (ASTM D 714)

Salt Spray Resistance
1500 Hours of Salt Solution:
Minimum Rating of 7 on Scribe or Cut Edges;
Minimum Blister Rating of
8 in the Field (ASTM D 1654)
3000 Hours of Salt Solution:
Minimum Rating of 7 on Scribe or Cut Edges;
Minimum Blister Rating of
8 in the Field (ASTM D 1654)




Weathering
Resistance

Accelerated
Exposure
1000 Hours in Atlas Type "XW" Weatherometer:
No Adhesion Loss;
Slight Chalking or Color Change
 

None Specified


Outdoor
Exposure

1 Year South Florida: No Adhesion Loss;
Slight Chalking or Fading
5 Years South Florida: 5 Delta E
(Hunter) Maximum Color Change;
Chalking < 8 (ASTM D 4214);
Gloss Retention > 30%
Erosion Resistance < 10% Film Loss

20% More Aluminum for strength you can count on!
We Don't Cut Corners.
We don’t cut corners; we push everything to the edge!

Was this article helpful?

Related Articles